• Skip to main content
  • Skip to secondary menu
  • Skip to primary sidebar
Schiller and Hersh Associates, Inc.

Schiller and Hersh Associates, Inc.

Consulting M/E/P Engineers

636 Skippack Pike, Suite 200
Blue Bell, PA 19422
P: 215.886.8947
F: 215.886.8956
  • Home
  • Firm
    • Mission
    • Staff
    • Client Testimonials
  • Services
  • Portfolio
    • Airports
    • Correctional Facilities
    • Energy Audits
    • Governmental
    • Green Building
    • Higher Education
    • Historic
    • Industrial
    • K – 12
    • LEED Certified Design
    • Religious
    • Senior Living
    • Solar Energy
    • Transportation
    • Water-Wastewater
  • Careers
  • News & Announcements
  • Contact
You are here: Home / Portfolio / Neumann University Student Health & Life Sciences Addition & Renovations

Neumann University Student Health & Life Sciences Addition & Renovations

Neumann RAB Addition, Neumann University, Aston, PA

Scope:  Schiller and Hersh Associates, Inc. provided Mechanical, Electrical, Plumbing and Fire Protection Design and Construction Administration services for the expansion and renovations to the RAB Building, which included a new 315 seat auditorium, AT/PT classrooms, AT/PT labs, administrative offices, conference rooms, and gang toilet rooms.  The project included:

  • Funding by the RACP program in PA, so project documentation had to comply with applicable requirements. 
  • Gas-fired, DX RTU VAV systems with dehumidification capabilities and improved acoustic design for noise control. 
  • New gas-fired, DX dedicated outside air RTU for the existing RAB building for dehumidification of outside air supply to the building.
  • Conversion of electric to gas-fired boilers for the existing RAB building. 
  • New high efficiency, condensing style boilers for the new addition. 
  • Web-based HVAC DDC control system design. 
  • Upgraded MDP to accommodate utility transformer increase.
  • High efficiency LED lighting systems with computerized lighting controls.
  • Electrical power systems.
  • AVT was a sub-consultant to S&H for all audio/visual system design on the project. 
  • Coordination with other consultants for the following electrical systems:  Fire alarm, low-voltage IT systems and audio/visual systems; all power, conduits, backboxes and cable tray systems were designed based on the coordination with other consultants. 
  • Plumbing systems including cold & hot water, sanitary, waste and vent systems, gas piping and low-flow plumbing fixtures.
  • New gas service to the RAB building from PECO. 
  • Fully sprinklered building. 

March 11, 2020
Filed Under: Higher Education, Portfolio

Primary Sidebar

Our Services

  • Mechanical
  • Electrical
  • Plumbing
  • Fire Protection
  • Energy & Sustainability

Contact Us

  • This field is for validation purposes and should be left unchanged.

Copyright © 2025 ยท Schiller and Hersh Associates, Inc. All Rights Reserved.
Website Design and Development by GetPhound.

Schiller and Hersh Associates, Inc.
  • Home
  • Firm
    • Mission
    • Staff
    • Client Testimonials
  • Services
  • Portfolio
    • Airports
    • Correctional Facilities
    • Energy Audits
    • Governmental
    • Green Building
    • Higher Education
    • Historic
    • Industrial
    • K – 12
    • LEED Certified Design
    • Religious
    • Senior Living
    • Solar Energy
    • Transportation
    • Water-Wastewater
  • Careers
  • News & Announcements
  • Contact