Rider University Wright and Ridge Residence Hall Renovations

Client: Rider University

Project Name: Wright Hall and Ridge Hall Renovations

Project Size: Wright Hall – 3-story 23,000 sf

Ridge Hall – 2-story 10,600 sf

Scope of work:

  • Design of new electrical services to the buildings, including campus 5kV campus upgrades, as required. 
  • Electrical service upgrade to the GSB building to allow the existing Ridge service to support the Ridge House until future renovations of other adjacent dorms are completed. 
  • Electrical service upgrade to Wright. 
  • Design of new receptacles and power in each dorm room for general use.
  • New electrical panels on each floor with new feeders with spare capacity for future upgrades.
  • Electronic metering of the electrical service.
  • New Dimmable LED Interior Lighting 
  • Design of new HVAC upgrades in the form of individual room electric Packaged Thermal Air Conditioning Units.
  • Design of new HVAC makeup air systems for heating and AC in the new shower / toilet rooms.
  • Design of new plumbing systems for the showers / toilet rooms.
  • Design of sprinkler modifications to accommodate new ceilings. 
  • Upgraded chiller system with all new pumps, piping and distribution for the Pavilion and Davis Center (adjacent basketball practice facility).
  • Upgrading heating system, pumps and piping distribution with separate heat exchangers for the Pavilion and Davis Center. 
  • New 4-pipe HVAC air handling units with DDC controls for the interior addition and renovated areas. 
  • New make-up air and exhaust systems for the commercial kitchen, concession and restroom facilities.
  • New relief fan and building pressurization controls for the main arena spaces.
  • New mini-split DX heat pump systems for audio/visual and broadcast rooms, which require year-round cooling. 

November 18, 2018
Filed Under: Higher Education

Primary Sidebar

Our Services

  • Mechanical
  • Electrical
  • Plumbing
  • Fire Protection
  • Energy & Sustainability

Contact Us

  • This field is for validation purposes and should be left unchanged.

Copyright © 2025 ยท Schiller and Hersh Associates, Inc. All Rights Reserved.
Website Design and Development by GetPhound.

Schiller and Hersh Associates, Inc.
  • Home
  • Firm
    • Mission
    • Staff
    • Client Testimonials
  • Services
  • Portfolio
    • Airports
    • Correctional Facilities
    • Energy Audits
    • Governmental
    • Green Building
    • Higher Education
    • Historic
    • Industrial
    • K – 12
    • LEED Certified Design
    • Religious
    • Senior Living
    • Solar Energy
    • Transportation
    • Water-Wastewater
  • Careers
  • News & Announcements
  • Contact