• Skip to main content
  • Skip to secondary menu
  • Skip to primary sidebar
Schiller and Hersh Associates, Inc.

Schiller and Hersh Associates, Inc.

Consulting M/E/P Engineers

636 Skippack Pike, Suite 200
Blue Bell, PA 19422
P: 215.886.8947
F: 215.886.8956
  • Home
  • Firm
    • Mission
    • Staff
    • Client Testimonials
  • Services
  • Portfolio
    • Airports
    • Correctional Facilities
    • Energy Audits
    • Governmental
    • Green Building
    • Higher Education
    • Historic
    • Industrial
    • K – 12
    • LEED Certified Design
    • Religious
    • Senior Living
    • Solar Energy
    • Transportation
    • Water-Wastewater
  • Careers
  • News & Announcements
  • Contact
You are here: Home / Portfolio / Correctional Facilities / Mountainview Youth Correctional Facility Fire Detection & Suppressions Study

Mountainview Youth Correctional Facility Fire Detection & Suppressions Study

Client/Owner: State of New Jersey / Department of Corrections

S&H performed a study of the fire alarm and fire protection systems at a total of (11) buildings at the Mountainview facility:

  • Cottages 1 to 4.
  • Cottages 5 to 8.
  • Administration Building.
  • Assembly / Gym Building.
  • Food Service Building. 

Scope of work:

  • Onsite field walk-thru of each building, including the assessment of the existing fire alarm and sprinkler systems relative to code and also existing conditions. 
  • Analyze the existing Clinton Water tank storage system and gravity feed to the facility, including obtaining water flow tests. 
  • Attend onsite excavation work to identify the location, size and material type of the existing incoming main onto the campus. 
  • Analyze the combined fire/domestic water system and determine requirements for separation. 
  • Review piping material types, including combined fire/domestic water lines. 
  • Review existing pathways for adding in fiber for communications back to the Administration Building for new fire alarm systems from various buildings. 
  • Review of the existing center control conditions to support a Proprietary Supervising Station System as per NFPA 8.4. 
  • Analysis for a new site located fire pump that is diesel fired and self-contained. 
  • Analysis of the existing site hydrants and the combined piping with the domestic water systems with no backflow prevention. 
  • Narrative report with a summary of the existing conditions, code analysis and recommendations.
  • Cost estimate with costs based on 2017 construction dollars. 

November 19, 2017
Filed Under: Correctional Facilities, Governmental

Primary Sidebar

Our Services

  • Mechanical
  • Electrical
  • Plumbing
  • Fire Protection
  • Energy & Sustainability

Contact Us

  • This field is for validation purposes and should be left unchanged.

Copyright © 2025 ยท Schiller and Hersh Associates, Inc. All Rights Reserved.
Website Design and Development by GetPhound.

Schiller and Hersh Associates, Inc.
  • Home
  • Firm
    • Mission
    • Staff
    • Client Testimonials
  • Services
  • Portfolio
    • Airports
    • Correctional Facilities
    • Energy Audits
    • Governmental
    • Green Building
    • Higher Education
    • Historic
    • Industrial
    • K – 12
    • LEED Certified Design
    • Religious
    • Senior Living
    • Solar Energy
    • Transportation
    • Water-Wastewater
  • Careers
  • News & Announcements
  • Contact